FIRE ALARM SYSTEM
Crafting Innovation
Norden has built a strong reputation for delivering innovative, reliable solutions across various industries, with a
focus on safety, quality, and performance. Specialising in advanced technologies, Norden offers a wide range of
solutions, from communication networks to security systems, all designed to enhance operational efficiency and
safety in diverse environments.
Among its key offerings, Norden’s fire alarm systems play a critical role in protecting life and property. These systems
are essential for early fire detection, providing timely alerts to minimise damage and ensuring a rapid response.
Suitable for residential, commercial, and industrial spaces, Norden’s fire alarms are designed to integrate
seamlessly with emergency services, complying with regulatory standards while offering peace of mind. By
addressing both safety and compliance needs, Norden’s fire alarm systems ensure the highest levels of protection
against fire risks.
NORDEN FIRE ALARM SYSTEM
FIRE ALARM PANEL
Single/2/4 Loop Intelligent Addressable Fire Alarm Control Panel
INITIATING DEVICE
Intelligent Addressable Optical Smoke Detector
Intelligent Addressable Heat Detector
Intelligent Addressable Multi Detector
Intelligent Addressable Manual Call Point
INTERFACING MODULE
Addressable Input Output Control Module
DETECTOR BASES
Sounder Flasher Base
Isolator Base
NOTIFICATION APPLIANCES
Addressable Sounder Strobe
ACCESSORIES
Programming Tool
Repeater Panel
Remote indicator
Loop Card
Network Card
Graphic Work Station
FIRE ALARM PANEL
SINGLE/2/4 LOOP
INTELLIGENT ADDRESSABLE FIRE ALARM CONTROL PANEL
FEATURES
LPCB Approved
254 devices per loop
1/2/4 loop in Network application
Built in 4 in 1 communication card
6 Loop can support in stand alone basis
Networkable upto 512 Nodes
Dedicated 2 loop for NAC
Programmable capacity
Sounder groups 1-1000
Module groups 1001-2000
Zones up to 3000
Built -in 160 LED Zones indicator
INITIATING DEVICE
INTELLIGENT ADDRESSABLE
OPTICAL SMOKE DETECTOR
The NFA-T01SD is an advanced Intelligent optical
smoke detector which having inbuilt intelligent
processor that provides algorithm map, Inbuilt
Analogue to Digital convertor, Drift compensation,
Self diagnosis and History log. The NFA-T01SD
Intelligent optical smoke detector is produced in
accordance with the EN 54-7 standard.
FEATURES
LPCB Approved
EN 54-7 :2018 Certified
Inbuilt microprocessor with memory capacity
up to 10 events
Digital addressing and Analogue sensing
Smart linear drift compensation
Provide real time algorithm to the
Fire alarm panel
360˚ Visual LED indicator
Ancilliary remote indicator
Onsite adjustable parameter
Removable chamber for service
INTELLIGENT ADDRESSABLE
HEAT DETECTOR
The NFA-T01HD is an advanced Intelligent Addressable
Heat Detector manufactured in accordance with the
EN 54-5 standard. Which having inbuilt intelligent
processor that provides Analogue to Digital convertor,
Self diagnosis and History log. Additionally, the Fixed
and Rate of Rise in temperature methods of sensing are
used in the construction of the NFA-T01HD Intelligent
heat detector.
FEATURES
LPCB Approved
EN 54-5 :2017 + A1:2018 Certified
Inbuilt microprocessor with memory capacity up to
10 events Digital addressing and Analogue sensing
Fixed and Rate of Rise in Temperature sensing
Provide real time algorithm to the Fire alarm panel
360˚ Visual LED indicator
Ancilliary remote indicator
Onsite adjustable parameter
INTELLIGENT ADDRESSABLE
MULTI DETECTOR
The NFA-T01MD is a modern Intelligent Addressable
Multi Detector that combines a Smoke and Heat
detection element into one unit. Additionally, the
NFAT01-MD Multi Detector is produced in compliance
with EN 54-29 standards. Which having inbuilt
intelligent processor that provides Algorithm map,
Analogue to Digital convertor , Drift compensation, Self
diagnosis and History log.
FEATURES
LPCB Approved
EN 54-29: 2015
Smoke and Heat sensor
Inbuilt microprocessor with memory capacity
up to 10 events
Digital addressing and Analogue sensing
Smart linear drift compensation
Provide real time algorithm to the Fire alarm panel
360˚ Visual LED indicator
Removable chamber for service
Ancilliary remote indicator
Onsite adjustable parameter
INTELLIGENT ADDRESSABLE
MANUAL CALL POINT
The NFA-T01CP is an Addressable Manual Call Point is
using microprocessor technology. It enable the
system to get the swift response from the call point to
Fire Alarm Control Panel. The NFA-T01CP Manual Call
Point use a non-breakable glass. Applying light
pressure on the Manual Call Point will trigger the
alarm signal, and inbuilt LED will turn on to steady light.
Using reset key and protected flap Manual Call Point
can reset. The NFA-T01CP Addressable Manual Call
Point is is produced in accordance with the EN 54-11
standard.
FEATURES
LPCB Approved
EN 54-11 :2001 + A1:2005 Certified
Inbuilt Microprocessor
Digital Addressing
Non Breakable Glass With Reset Key
Semi Flush Mounted And Indoor Application
Safe To Operate And Easy To Restart
INTERFACING MODULE
ADDRESSABLE INPUT OUTPUT
CONTROL MODULE
The NFA-T01CM Addressable Input Output Control
Module basically multifunction module, it can act
alone as Input module, Output module or Control
module. NFA-T01CM plays a major role in interfacing
third party system into Fire alarm control panel. The
Control module used for overriding equipments like
Lift return, Door holder, Extract fans, Air Handling Unit
etc. And it incorporates an intelligent processor that
provide automatic monitoring for both open and
short circuit of Input signal line. The NFA-T01CM
manufactured in accordance with the standard
EN 54-18.
FEATURES
LPCB Approved
EN 54-18 :2005 Compliance
Built in microprocessor and digital addressing
Fire or supervisory Input signal configuration
24VDC /3A Output Relay contact and Control module
Onsite Adjustable Parameter
Loop or external power input
LED Status indicator
Surface mounting
DETECTOR BASES
SOUNDER FLASHER BASE
The NFA-T01SB Sounder Base is the cutting edge
device manufactured to meet special requirement
of notify individuals in the proximity of a fire
emergency, prompting to take necessary precautions.
The NFA-T01SB Sounder Base comes with the
combination of Sounder and Flashing beacon or
Sounder and Flashing beacon alone, we can configure
this by use of Programming tool. In addition we can
configure the alarm tone according to the requirement
from 17 different tones. The NFA-T01SB Manufactured in
accordance with EN 54-3 and LPCB approved.
FEATURES
LPCB Approved
EN 54-3 :2014 + A1:2019 Certified
Built in processor and digital addressing
Encoding modes such as Single encoding mode,
Dual encoding mode 1 and 2
17 tones programmable sound output (Tone, 14, 16, 17 are
recognized by LPCB)
8 highlights LED status cluster
Programmable Evacuate or Pre alarm signal
Loop power input
ISOLATOR BASE
The NFA-T01IB Isolator Base is the cutting edge device
manufactured to protect devices in loop from short
circuit. In the event of short circuit on the loop the
NFA-T01IB Isolator Base isolate the unaffected devices
from short circuit and it will work normally. The base
mount short circuit isolator will automatically restore
the affected portion of the loop after clearing the fault
and continuing to monitor for repairs. The NFA-T01IB
Manufactured in accordance with EN 54-17 and LPCB
approved.
FEATURES
LPCB Approved
EN 54-17:2005 Certified
LED Status Indicator
In The Event Of Short Circuit Isolates The Faulty
Part Of The Loop.
Automatically Resetting Once The Fault Is Cleared
Can Monitor Upto 70 Devices
Surface Mounting Installation
NOTIFICATION APPLIANCES
ADDRESSABLE SOUNDER STROBE
The NFA-T01ST Addressable Sounder Strobe is an alarm
warning device used to alert individuals in the vicinity of
a fire emergency, prompting to take necessary
precautions. The NFA-T01ST Sounder Strobe combines
multiple applications, including various types,
parameters, and wiring layouts within a single device.
Using a programming tool, the NFA-T01ST can be
configured for different alarm warning modes, such as
sounder strobe, sounder only, or strobe only.
Additionally, parameters can be adjusted to meet
specific requirements, including selecting from 17
different alarm tones, choosing between single or dual
address modes, and optimizing power consumption
through simple programming. The NFA-T01ST
Manufactured in accordance with EN 54-3 and LPCB
approved.
FEATURES
LPCB Approved
EN 54-3:2014 + A1:2019 Certified
Built in Processor and digital addressing
Programmable types such as sounder strobe,
sounder or strobe alone 17 tones programmable
sound output
Programmable Evacuate or Pre alarm signal
One or Two address mode
10 Highlights LED status cluster
Loop or external power input
Onsite adjustable parameter
ACCESSORIES
PROGRAMMING TOOL
The NFA-T01PT serves as a versatile programming
tool for the NFA-T series of products. Designed to
accommodate various device parameters, including
address, sensitivity, mode, and types, it ensures
compatibility with site-specific conditions and
environmental requirements. Additionally, this
programmer can retrieve previously encoded
parameters for testing and troubleshooting purposes.
Its compact and robust design makes it convenient for
use in the workplace. The NFA-T01PT comes equipped
with twin 1.5V AA batteries and a cable, ready for
immediate use upon receipt. With an intuitive display
and functional keys, it allows for easy activation of
commonly used parameters.
FEATURES
Write, read and delete device parameters
Pluggable cable with end alligator clip to hold
tight the terminals
LCD display and functional keys
Low current consumption for longer battery
life span
Circuit protection against clip
Auto power off within 3 minutes
REPEATER PANEL
The NFA-T01RP Repeater Panel is designed with a built-in
MCU processor to display precise fire event messages
from the control panel. It provides fast relay response with
simultaneous audible and visual signals. Additionally, this
Repeater Panel can be programmed to limit zone display
to a specific zone or three adjacent zones using the
panel's key buttons. It connects through the
communication loop of the NFA-T04FP Intelligent
Addressable Fire Alarm Control Panel and supports
installation of up to 254 units per loop. When there's a
need to relay information to multiple points, this repeater
panel serves that purpose. It complies with the EN 54-2
standard and features a compact, aesthetically pleasing
design.
FEATURES
EN54-2 Compliance
Loop Fire display passive repeater panel
Built-in mcu processor and digital addressing
Fast response of audible and visible signal from the
panel
Programmable zone display such as all zone,
Single zone and three adjacent zone
LED status indicator
Loop sited wiring with external 24V supply