Crafting Innovation
Norden is one of its own kind manufacturer and supplier of
the ELV and Optical Solutions and Data Centre solution of
all kinds that have been tried and tested and cater to a wide
spectrum of environments such as the telecommunications,
buildings, utilities and industries, surveillance systems and
Public Addressing Systems. The company provides some of
the exemplary devices and solutions having the best modern
technology as their working foundations.
POWERING LIVES,
THROUGH INNOVATION
EXPLORING TECHNOLOGY
FOR A BETTER WORLD!
www.nordencommunication.com
VISION
To gain global recognition through top-notch solutions and innovative products that
redefine excellence. We strive to deliver the best products that are incorporated with
futuristic technology. Striding ahead with this meticulous and optimistic attitude, we
envisage becoming the most credible brand and the industry leader through our
advanced product lineup. A well-defined and refined process, formulated by our
expert professionals, is driving us ahead with solid steps. In the endeavour to be the
most reliable brand in the sector.
MISSION
Striving for excellence, we introduce novel concepts and induce the latest
technological developments. Sustainable business development methodologies,
designed by a team of experienced technical professionals, have been the mainstay
behind our growth. Our mission since establishment remained the same, to emerge
as the name synonymous with quality, performance and excellence. Implementing
measures that deliver optimal results and fortify our objective, we continue to climb
the ladders of success. Customer satisfaction has been the catalyst that drives us
forward confidently.
www.nordencommunication.com
NORDEN COMMUNICATION
AN ACTIVE INTERNATIONAL PRESENCE,
CONNECTING MARKETS GLOBALLY
www.nordencommunication.com
DATA CENTRE SOLUTION
www.nordencommunication.com
The increasing development of cloud computing and mobile internet has presented traditional data centres with numerous
challenges, including extended construction cycles, high initial investments, low efficiency during low loads, challenging
expansion during high loads, and overall low management efficiency. In server rooms that have not been designed as data
centers, the permanent mixing of cooled and heated air often leads to cooling deficits. Hot spots make the IT equipment’s
work more difficult. So Norden has developed a solution for this by using Hot/Cold containment system.
BENEFITS AT A GLANCE
• Intake air (cold) and waste air (hot) are unable to mix
• Modular, scalable and upgradable
• An inexpensive solution for the optimum cooling of existing data centers
• Eliminates the need for humidifiers, saving energy and water
• Reduces over-provisioning and waste related to room upgrades and modifications
• Sliding lockable doors
AISLE CONTAINMENT SYSTEM
www.nordencommunication.com
COLD AISLE WITH RAISED FLOOR
HOT AISLE CONTAINMENT SYSTEM
• Centralized AC system supply cooled air into cold aisle via perforated tiles of raised floor.
• Cold aisle containment offers various benefits, including ease of implementation without the need for additional
architectural modifications to man age exhaust air. It simply requires the installation of doors at the aisle ends and a roof.
This makes it a cost-effective and adaptable choice for retrofitting existing data centres, especially those with overhead
obstructions like existing ductwork, lighting, power systems, and network distribution.
• Even with low room heights, the raised floor height is maximised for cooling air supply without flow losses.
• Cold Aisle Containment isolates the cooled supply air from the CRAC units within direct proximity of the air intake of
critical equipment.
• Undisturbed and uniform air flow distribution of cooling air in the cold aisle guarantees high efficiency.
• Favourable working conditions in the cold aisle due to low temperature, flow and noise load conditions
• Hardware racks not connected to the enclosure do not impair the cooling efficiency of the cold aisle.
• Use of inexpensive standard CRAC cooling units sited outside of the server area.
• Establish optimal operating efficiencies.
• Improved PUE, lower carbon emissions, extending IT equipment life, potentially fewer equipment failures due to
overheating and aesthetic.
• Open Area of the room is cold environment.
• Leakage from raised floor openings in the larger area of the room goes into the cold space.
• Hot aisle containment will be more forgiving for network racks and stand-alone equipment such as storage cabinets that
might have to live outside the containment architecture.
• Separates supply and return airflow which provides a uniform and predictable to both IT temperature and AC equipment.
• Eliminates hot and cold air mixing.
• Works in both a raised floor and slab environments.
• Improved cooling efficiency: By isolating hot air from the cold air supply, the cooling system can operate more efficiently,
reducing energy consumption and costs
• Increased equipment reliability: By maintaining optimal operating temperatures, hot aisle containment can help extend
the lifespan of IT equipment and reduce the risk of overheating-related failures.
• Better airflow management: Containing hot air allows for more precise control over airflow patterns within the data
centre, ensuring that cool air is delivered where it’s needed most
• Higher density deployments: With better cooling efficiency and airflow management, data centres can often support
higher server densities, maximizing the use of available space.
www.nordencommunication.com
CONTAINMENT SYSTEM
Norden Aisle Containment Systems are engineered to meet the challenges of contemporary data centers by optimizing
thermal management, boosting energy efficiency, and ensuring operational dependability. These systems effectively
separate hot and cold air, reducing energy usage and preventing overheating of critical equipment.
The system seamlessly integrates core data center functions into a unified solution, including power supply, UPS,
cooling system, cabinets, closed channels, and dynamic environmental monitoring. Equipped with advanced sensors,
it allows for real-time monitoring, automatic control, and intelligent operation, significantly enhancing the reliability,
availability, and ease of maintenance for modern data centers
AISLE CONTAINMENT SYSTEM
FEATURES
•
High Reliability: Prefabricated design with redundant components to ensure strong system performance.
•
Intelligent Management: Real-time notifications via various channels and user-friendly remote and local interfaces.
•
High Efficiency: Modular UPS, integrated power distribution, and energy-efficient cooling solutions.
•
Simple Installation: Standardized modular design with hot-swappable components for easy installation and maintenance.
•
Norden’s Aisle Containment System offers intelligent, efficient, and reliable solutions, making it an
excellent choice for data centers of the future
www.nordencommunication.com
SMART CABINET
FEATURES
• High Reliability : Engineered prefabrication and redundant system design ensure exceptional stability and dependability.
• Intelligent Management : Advanced monitoring capabilities enable real-time alerts via SMS, phone calls, emails, and
audio-visual signals. Users can interact through remote apps, local LCDs, and web interfaces.
• Energy Efficiency : Equipped with an intelligent modular UPS, integrated power distribution, and precision cooling,
ensuring optimized PUE (Power Usage Effectiveness).
• Rapid Deployment : Pre-installed at the factory with a modular plug-and-play design, enabling quick setup and
consistent standardization across multiple locations.
Norden Smart Cabinet is a cutting-edge, modular, self-contained micro data center designed to support rapid and
secure IT deployments. It accommodates up to 15 racks and integrates essential systems such as cooling, UPS,
power distribution, and emergency ventilation. This solution is ideal for small and campus data centers and caters to
diverse industries including banking, financial services, insurance, education, healthcare, manufacturing, retail, and
transportation.
www.nordencommunication.com
NORDEN FIBRE SOLUTION
HIGH-DENSITY MODULAR FIBRE OPTIC PANEL
FEATURES
High-Density Modular Fibre Optic Panel offers an
efficient inter-connect or cross-connect solution between
backbone cables and active equipment. It supports
both field termination of connectors and pre-terminated
solutions, making it ideal for high-density data center
applications.
• 1U capacity with 144 cores and up to 12 cassettes.
• 3 sliding drawers for easy access, with each drawer accommodating 4 modular cassettes.
• Rear and side entries for trunk cabling, with a removable cover for easy installation.
• Compatible with LC, SC, MTP, and splice cassettes.
www.nordencommunication.com
10
HIGH-DENSITY RACK MOUNT FIBRE PATCH PANEL-SNAP-IN SUB-MODULE TYPE
High-density rack-mount snap-in sub-type fiber patch
panels are designed for plug-and-play data center
systems, supporting High Density LC/SC and MTP/
MPO modules. These 1U drawer-type panels feature a
lockable front for security and include cable managers for
organized routing of patch cables. They are compatible
with splicing and pass-through solutions.
FEATURES
• Easy front access for convenient operation.
• 1U 19” rack mount design.
• Accommodates up to 4 Snap-in Sub modules in 1U.
• Lockable front panel for added protection of trunk cables and patch cords.
• Supports splicing and pass-through solutions.
• Three rear cable entry holes (one for pass-through, two for fiber).
• Contains two 48F splice trays.
FEATURES
HIGH-DENSITY MTP/MPO FIBRE PATCH PANEL
• Designed to fit standard racks.
• Small size MTP/MPO module with high capacity.
• Compatible with LC and SC adaptors
• Drawer-type for easy installation and fibre management, reducing construction costs.
• Ideal for data centres and network rooms.
High-Density MTP/MPO Fibre Optic Patch Panels are
designed for fast connections and efficient distribution
of backbone cables in the Main Distribution Area (MDA).
Available in 1U and 4U configurations for standard 19”
racks, they support LC, SC and MTP/MPO cassettes,
making them ideal for high-density fibre distribution
in data centres. These panels help streamline network
deployment while optimizing space and maintaining
performance in high-capacity environments.
www.nordencommunication.com
11
HYBRID HIGH DENSITY PATCH PANEL & PRE-TERMINATED SOLUTION
MTP/MPO HIGH DENSITY PATCH PANEL
FEATURES
FEATURES
• Copper cassettes are available in Category 5E, Category 6, and Category 6A, offering both
screened (STP) and unscreened (UTP) options.
• Fiber cassettes come in 24 or 12 ports for LC or SC types and also support MPO/MTP solutions.
• The patch panel can hold up to four cassettes.
• Pre-terminated solutions can be customized for cable type and length.
• High-density 1U panel supports up to 96 cores.
• Drawer type with a transparent PC front cover for easy observation and maintenance.
• Simple button mechanism for opening and closing the panel cover.
• Equipped with a locking device to prevent the drawer from falling when in motion.
• Two oval cable entry ports on the rear side for easy cable management.
• Compact and easy to install design, making it suitable for high-density applications.
Hybrid High-Density Patch Panel allows both copper
and fibre terminations in a single unit. It’s designed for
quick installations, making it ideal for data centres and
environments where fast deployment is critical. With a 1U
high-density blank panel, it accommodates four fibre or
copper cassettes using various types of adapters. This
flexibility enables data centre managers to easily adapt to
network growth, changes in business needs, or migration
strategies, ensuring efficient management and scalability.
The MTP/MPO high-capacity fibre optic distribution
frame is designed for fast and efficient fibre cable
connections and distribution. It supports the use of MTP/
MPO connectors and ribbon fibre cables, providing an
easy plug-in connection. This frame is ideal for high-
density capacity data canters, enabling streamlined
fibre management and distribution. Its design simplifies
installation and ensures effective fibre optic distribution in
demanding environments.
www.nordencommunication.com
12
HIGH-DENSITY FIBRE OPTIC DISTRIBUTION FRAME
High-Density Fibre Optic Distribution Frame offers
flexible cabling access, an expandable frame design, and
integrated cable management. Its future-proof, modular
structure ensures the highest possible termination
capacity with superior management of cables. The side-
access patch panel design allows for various applications,
including termination, splicing, and storage, making it
ideal for high-density fiber deployments in data centers.
FEATURES
• Standard 19” & ETSI installations
• Maximum fiber density of 2016 ports for splicing and patching
• Slot-type cable guide compartments for efficient module feeding
• Wide range of splice, patch, and storage options
• 35 mm bend radius protection throughout the frame
• Interchangeable cassettes for different cable and connector types
• Compatible with micro splitters
• Integrated patch cord management
HIGH DENSITY FLOOR STANDING FIBRE OPTIC DISTRIBUTION FRAME
High Density Floor Standing Fibre Optic Distribution
Frame offers a robust solution for efficient fibre
management in demanding environments. Constructed
from high-quality steel and aluminium alloy, it features
anti-corrosion treatments and ensures structural integrity.
With flexible cabling access, an expandable design, and
integrated cable management, it supports both loose
bundle and ribbon cables. Its modular design allows
for high termination capacity and versatility, making it
ideal for modern data centres and telecommunications
applications.
FEATURES
• Features centrally positioned 19” mounting rails for Optical Distribution Frames (ODFs).
• Offers ample space for fibre distribution and storage, facilitating easy installation and maintenance.
• Allows full front-side access for convenient servicing.
• Maintains a controlled minimum bend radius of 30mm with adjustable cable guides.
• Includes dual lateral canals with independent doors for effective cable management.
• Side-hinged doors enhance security for patch cord distribution.
• Supports top or bottom cable routing and is suitable for both loose bundle and ribbon cables.
• Equipped with a secure cable fixture cover and grounding system.
• Available in standard colors (white, black, grey) with custom options upon request.
www.nordencommunication.com
13
MTP/MPO TRUNK & FAN - OUT HYDRA CABLE
MTP/MPO Trunk and Fan-out trunk patch cords offer
a quick installation solution for high-density backbone
cabling in data centres. They provide flexibility for
unplugging and reusing cables, making them ideal for
environments requiring rapid deployment. These factory
pre-terminated MTP trunk cables are available with OM3,
OM4, and SM assemblies, ensuring high performance in
fibre environments.
FEATURES
• Factory-terminated systems reduce installation and network reconfiguration time.
• High-standard components are utilized to ensure product reliability.
• These systems are factory terminated and rigorously tested.
• They facilitate seamless upgrades from 10GbE to 40GbE or 100GbE.
• Ideal for 400G high-speed network connections.
Hybrid High-Density Modular Fixed Panel can hold up
to 4 HD modules or HD pass-through adapter plates,
supporting a total of 96 fibres with LC configuration.
It’s designed for versatile applications with MTP/MPO
systems, pre-terminated cables, or standard splicing. The
panel provides easy front access and includes a cable
management bar to protect patch cords, making it an
efficient solution for high-density environments.
HYBRID HIGH-DENSITY MODULAR FIXED PANEL
FEATURES
• 4 High Density slots in 1U.
• Supports up to 96 fibres (LC configuration).
• Compatible with MTP/MPO modules or adapter plates.
• Modular design adapts to various modules and adapter plates.
www.nordencommunication.com
14
PRE-TERMINATED FIBRE CABLES
Pre-Terminated Break Out patch cord features tight-
buffered fiber within a common outer jacket available
in OM1, OM2, OM3, OM4, OS1, and OS2 multi-mode
and single-mode variants. Each end is terminated with
high-performance hybrid or single connectors, such as
SC, ST, FC, LC, MTRJ, or E2000, in simplex and duplex
configurations. Utilizing pre-terminated patch cords
simplifies installation and minimizes the need for on-site
terminations, making them ideal for various networking
applications.
FEATURES
• Pre-terminated Break Out patch cords feature tight buffer fiber within a common outer jacket,
available in multi-mode and single-mode options.
• Each end is fitted with high-performance hybrid or single-type connectors in simplex and
duplex configurations.
• Designed for easy installation in cable trays, these cords can accommodate up to 144 core
LC/SC patch cords, tailored to the required length.
UNIBOOT LC - LC / SC FIBRE PATCH CORD
MTP/MPO Trunk and Fan-out trunk patch cords offer
a quick installation solution for high-density backbone
cabling in data centres. They provide flexibility for
unplugging and reusing cables, making them ideal for
environments requiring rapid deployment. These factory
pre-terminated MTP trunk cables are available with OM3,
OM4, and SM assemblies, ensuring high performance in
fibre environments.
FEATURES
• Factory-terminated systems reduce installation and network reconfiguration time.
• High-standard components are utilized to ensure product reliability.
• These systems are factory terminated and rigorously tested.
• They facilitate seamless upgrades from 10GbE to 40GbE or 100GbE.
• Ideal for 400G high-speed network connections.
www.nordencommunication.com
15
CAT6A UTP/FTP BENDABLE BOOT PATCH CORD
Innovative bendable strain relief boot is designed to
safeguard cables at critical bending points, enhancing
durability and reducing wear in vulnerable areas. This
feature is especially beneficial in tight installation spaces,
where it helps maintain the integrity of the cables over
time.
FEATURES
• Designed to protect cables at critical bending points, reducing wear and tear.
• The bendable design allows for easy adjustments in tight installation spaces.
• Helps maintain organized cabling by reducing strain at connection points.
• Suitable for various applications in data centers and networking environments.
• Simplifies the setup process in challenging or restricted areas.
NORDEN COPPER SOLUTION
www.nordencommunication.com
16
CATEGORY 8 S/FTP 4 PAIR 22 AWG CABLE
CAT8 COPPER PATCH PANEL BLANK
Category 8 S/FTP (Shielded Foiled Twisted Pair) 4-pair
22 AWG cables are designed for high-speed networking
applications,
offering
improved
performance
over
previous categories. They support data rates of up to 25
Gbps or 40 Gbps over short distances (up to 30 meters).
The S/FTP construction provides enhanced shielding
to reduce crosstalk and electromagnetic interference,
making them suitable for data centers and enterprise
environments. These cables are ideal for applications
requiring high bandwidth and low latency, such as 25G
Ethernet and 40G Ethernet connections.
Norden Cat 8 blank shielded patch panel surpasses TIA
and ISO standards, delivering exceptional performance
for LAN, multimedia, Power over Ethernet, and data
center applications. Its 19” frame allows for tool-free
installation of keystone outlets. Supplied unloaded, it
includes an earth cable for proper grounding to ensure
effective shielded system functionality. The tool-less jack
termination simplifies setup, offering speed, reliability,
and efficiency.
FEATURES
FEATURES
• Supports high-speed data transmission up to 40 Gbps.
• S/FTP design for enhanced protection against crosstalk and electromagnetic interference.
• 22 AWG, allowing for longer distances while maintaining signal integrity.
• 4 pairs of cables for improved performance.
• Weather-resistant, suitable for outdoor and harsh environments.
• Exceeds TIA and ISO specifications for high performance.
• Keystone outlets snap into place without additional tools.
• Comes with an earth cable for proper grounding.
• Numbered ports, label areas, and stress relief ensure organized and reliable setups.
• Simplifies setup in data centres and networking environments.
• Made from durable materials for long-lasting use.
www.nordencommunication.com
17
NORDEN INTELLIGENT PDU
PDU - LOCALLY MONITORED & REMOTE MONITORED
Norden Intelligent Monitoring Power Distribution Units
are engineered to enhance energy efficiency, ensure
uninterrupted uptime, and lower operational costs.
FEATURES
• Space-efficient structure for easy installation.
• Ensures reliable monitoring of power usage.
• Prevents accidental disconnections, reducing downtime.
• Allows for controller replacement or upgrades without power interruption.
• Supports connection in series for efficient power management.
• Adaptable output options to meet varying demands.
• Supports up to 42 IEC outlets for extensive connectivity.
www.nordencommunication.com
18
ENHANCED IP-PDU
Norden Enhanced Intelligent PDU offers advanced
network control and monitoring with the ability to turn on,
turn off, or reboot the power of individual outlets.
FEATURES
• Includes a high - resolution LCD display unit.
• Efficient use of space.
• Tracks breaker status continuously.
• Facilitates easy replacement.
• Reliable power usage tracking.
• Enables efficient connection.
• Prevents accidental disconnection.
• Scalable output options.
• Tracks environmental factors.
• Outlet on/off functionality.
• Supports multiple communication protocols.
• Tracks performance over time.
www.nordencommunication.com
19
NORDEN ENVIRONMENTAL SENSORS
NORDEN DOOR SENSOR
NORDEN SMOKE SENSOR
NORDEN TEMPERATURE & HUMIDITY SENSOR
The door sensor contacts to the host device and directly
monitors the open/close statues of door in the equipment
room. An alarm will be sent when the door is open.
The smoke sensor connects to the host device and
directly monitors smoky statues. When it exceeds the
limiting value, an alarm will be sent.
The T/H (Temperature/Humidity) sensor can monitor the
temperature and humidity in working environment.
www.nordencommunication.com
20